Mitsubishi Heavy FDC224KXE6


The manufacturer Mitsubishi Heavy (Japan)
Inverter Yes
Productivity in the cold (kW) 22.40
Performance of heat (kW) 25.00
(m2) 220
Noise level (dB) 58
Power supply (V / Hz / F) 380-415/50/3
starting current , 5.00 A
current on cooling and 9.25
for the heating current, 9.85 A
Power consumption for cooling, 5.60 kW
power consumption for heating, kW 6.30
Weight (kg) 221.00
Type of refrigerant R410
Dimensions (mm) 1675x1080x480
KX6 system is new, is the fourth generation of multi-zone VRF-systems, manufactured by Mitsubishi Heavy Industries. The range includes a low power system (the so-called mini-VRF), intended for residential air conditioning and small offices, and "full-size» VRF-systems for air conditioning systems of large area.
Range outdoor unit includes a cooling capacity of the model from 11.2 to 136 kW, with outdoor units capacity of 22.4, 28 and 33.5 kW are ultra-compact size (the smallest in the industry), which allows them to be mounted on the walls.
The range of indoor units includes 76 models of thirteen different types.
KH6 series systems have a number of innovative features that facilitate commissioning and maintenance (checking refrigerant, a self-test before the first start, etc.), making them one of the most convenient to install.
high efficiency and compactness achieved through the following technologies :
optimized the shape of the edges heat exchanger,
the optimum air velocity,
improved refrigerant distribution system
start time the air conditioner in a mode of heat greatly reduced.
Can operate at low outdoor temperatures (-15 ° C).
In 3D Scroll Compressor used spirals with different heights of external and internal parties. Thus, achieving a higher compression ratio by compressing the refrigerant, not only in the radial and axial direction.
Even with a high degree of compression is no reduction in efficiency. The strength of the spirals significantly improved by reducing the height of the inner loop of the spiral, which, when exposed to high work load.
New technology allows to achieve high efficiency.
smooth transition from low speed to high
sinusoidal voltage change.
CEE significant increase in the low rotation speeds.
The circuit is optimized taking into account the company's vast experience in the design of such systems and has the following primuschestva:
Optimal distribution of refrigerant to the heat exchanger.
Enhanced protection against ingress of liquid refrigerant to the compressor.
High-speed operation with a new version of SUPERLINK.
Application of DC motor has increased the efficiency by 60% compared with the old models.
fan design is created with the help of an aerospace division MHI - serrated blades can give a greater air flow at a lower cost of electricity.
to a series of outdoor units can be connected KX6 from 150% to 200% capacity index of indoor units (in series pedyduschey KH4 - 130%).Important:
When connecting an aggregate capacity of indoor units exceeds the total cooling capacity of the outdoor unit, under certain conditions, the maximum load capacity of each indoor unit can be significantly reduced.
Easy access to various sites to block by the division into compartments.
KH6 Series has a new means of troubleshooting. With the digital indicator on the board of the outdoor unit can track a variety of settings.With the seven-segment display, you can track emerging problem, and the story of their origin.
Outdoor units are equipped with RS-232 port for connecting directly to a PC and monitor the system using the program MENTE PC
FUNCTION TEST NUMBER OF REFRIGERANT: This function is a convenience.
weight of refrigerant to be monitored in the sluchae.Esli any inspection showed that the number does not correspond to the norm, it is necessary to take appropriate action to correct the number.
Even if the test passed, the result may depend on environmental conditions (ambient temperature). Thus, a one-time check can not cover all possible conditions. For security reasons, it is advisable to check the amount of refrigerant and permanently every year.
For more information, refer to the technical documentation.
In dvuhkompressornyh blocks, in the event of failure of one of the compressors, the system will continue to work on the proper compressor.In the case of combinatorial blocks, if one of the components of the units fails, the system will continue using the remainder.
Reducing Refrigerant: Apply pipe of smaller diameter, which reduces installation costs
Description